MediumRoastSteam
Great questions.
1: Only from the HW tap. Didn’t open both at the same time. After steaming, there was a very short fill as the pump kicked in. It might have lasted a few seconds.
2: Yes. The steam was from the HW tap, not only at the start, but throughout; there was hardly a steady flow of water. It has mostly been like that from day 1. It’s rare we get a steady flow of hot water without steam.
3: No. The service boiler doesn’t have a manometer.
4: When the service boiler is out of water, I typically get a lot of steam and a few drops of water. Sorry, I didn’t observe the steam boiler temperature.
I will fire the service tomorrow morning, wait for 15-20 mins, without steaming, draw water from the HW tap, measure the volume and temperature range, report back.
Thx
Edit :
The steam and hot water mix is like Spitting / sputtering water (steam, water and air). Is the service temp (130C) too high or trapped air ? This temp came as a default.