I’ve been using the low flow and preinfusion for ease of other users. I really wish (as was stated in the video as well) that there was an easy way to turn it in to “manual” mode without losing the settings so I can just use the paddle. Even better (which I hadn’t thought about before the video) would be having several “profiles” you could easily switch between.
My current settings (which seem to work more by luck than judgement) are pre infusion on for 6 seconds, off for 4 seconds and low flow for 8 seconds. That brings it up to roughly 2 bar and ends up with beading on the bottom of the portafilter but generally no drips in the cup.
I’m currently using 17.5g in the “double” basket and aiming for around 40g out in 40 seconds.
Edit: corrected typo