DavecUK
This would be my approach if it wasnāt for the fact that Iām literally on the other side of the planet and I donāt seem to be able to source the parts in Australia. Shipping time and cost from Europe makes this approach very inefficient, I want to be sure to order all the parts I need in one go.
So my plan is to leave the valve disconnected and bridge the contacts to simulate the low pressure/high pressure statuses and verify that the pump doesnāt run/ runs as it should and the machine doesnāt trip the rcd, which would tell me that the pressure stat is the only faulty part.
What I would like to know is how to bridge the three black, red and white wires to simulate the functioning of the pressure stat (open/close signal to the pump), obviously with an empty basket to avoid over pressurising the system