DavecUK You need to be super careful as you will tie yourself in nots and a lot of expense fixing things that are not faulty.
You had an AL11 fill timeout problem = faulty tank float switch or wiring
You had a steam boiler overfill event resulting in a steam and water excursion from the safety valve
Thank you Dave. Appreciate your replies, taking time to help us.
Agree. The last thing I want is spending hundreds on parts which are not required. I don’t want to.
I was wondering it would definitively be worth and safe to try replacing the faulty float switch with the wires.
Steam Boiler - safety valve resolved itself as the boiler came up to full temperature. No need to replace them.
DavecUK The key question is why is the steam boiler overfilling.
This was clearly triggered when the disconnected solar switch wire were connected. I have no clue / idea why it suddenly overfilled without stopping.
Did the fill probe sensor suddenly fail (the middle valve with a long steel arm with blue wire sticking out) ?
It worked flawlessly the week end before. After that, the steam boiler was pressed into service only this week end, when my daughter visited us for the long week end.
The alternative is wait out for a few days to allow those to dry fully. Fingers crossed, I hope the display and board are ok, saving £££. 😁 I have removed the sides and the top to allow some fresh air in.
The machine is under used. It comes into service only on week ends. Hahaha