MisterH1337 I’d ask your retailer to swap the HX temp probe (and not the service boiler temp probe) I think it might be faking on my machine, hence the PID makes bad decisions in thermal regulation.
From my understanding, there are two temperature sensors on the boiler, one on top and the other on the bottom?
Your retailer already replaced the sensor on top and that didn’t fix your issue, and now you will ask them to replace the bottom sensor as well as the gicar box?
I’m looking at Lelit Insider youtube videos and came across this one where he points to the NTC(?) probe @ 33 seconds which I assume is the other bottom sensor.
I’ll await your results after your next visit with your retailer and see if that fixes your issue (I wish I could bring mine in without shipping it - they’re 4+ hours away!). If it does fix your issue it looks like a fairly simple swap for the temp sensor - Lelit Insider has a separate video on replacing the top temperature sensor for steam and it was just a simple swap and I assume the same steps for the bottom sensor.
I also have to ask, when was your machine manufactured? Wonder if it’s a similar batch as mine was May 2021.