Hi Dave, I can’t recall exactly what the pressure gauge reading was but it never really changes so I’m presuming it was as the latest video ie pump pressure 9 bar & 2.5 bar static and boiler pressure at 1.2 bar.
I live in Glasgow so soft water here and the machine is plumbed in but the machine was bought from the North east of England so not sure if there is hard water there.
Regarding the group temperature I’ve tested it with thermocouples and the exit water with a temp pen and it’s never been cool but the coffee in the cup isn’t hot I’ve had it up to about 80 degrees c but sometimes its down to about 70 degrees c the temp of the coffee is what made me start looking at all of this.
This thread below contains some details of the temperature etc.
I’m going to get some fittings this afternoon to fit a pressure gauge to the PF but my understanding is that if the pressure at the PG on the PF is still 9 bar then that means there’s a blockage depending on the amount of water coming out of the group head but I tested that last week and it was 90g of water in about 60 seconds which is, as far as I can find out, isn’t too bad.
However if the pressure is well down at the PG on the PF then indicates either a blockage or a faulty pump?
I’ve cleaned out the dispersion screen and the shower screen and the filter and descaled the group head and also cleaned out the jet too.
I’ll post the PG/PF filter later on.
Reading the post below again then it’s obvious that the machine was probably blocked at that jet since I bought it or it got progressively worse over time however the coffee initially for at least a year after purchase was excellent consistently.
https://www.coffeeforums.co.uk/threads/elektra-t1-heat-exchanger-espresso-machine-cool-espresso.65862/#post-878851