deiadri Hi Adrian looks like the pump is running without the lever being pulled down (against a closed valve)? Then when you pull the lever, of course the group valve opens and the pump speeds up.
This leads me to believe you have a faulty pressurestat.
Which would probably be the reason for the “other” problem where the preinfusion pressure climbs too high.
I’ll grab a pressurestat from the spares box at the factory and bring it back with me on my flight tomorrow.
Send me an email with your address.
P.S. can you also send details of the problem to Maria at ACS and let her know I have taken a pressurestat for an Evo to bring back and post to you.