Inspirado Could it be the pressure stat and slow response? Or software?
My pump on the V2 kick on instantly the pressure in the brew circuit drops, so as soon as the water valve opens the pump comes on.
Itâs difficult to know what the problem is with your machine, because as soon as the water valve opens, your pump should also come on. It wonât be software. Some questions:
- when did it start doing this
- did you undertake any works on the machine which coincided with this happening
- Is the delay the same duration each time, or does it vary
It would be good to see a video of course (upload to YT and paste the link here. Some checks for you to perform
- There is a small lever which presses the water valve openâŚpush it backwards, how fast does the pump start
- is there a very large gap between the pin that is pushed to open the water valve and the little lever? Upload a photo if you want
Other than that, there is not really any reason for a delayed response, unless, you have a sticky pressure stat. In which case the solution is replacement with the same exact model (and the reason I asked question 3 above) and recommended the tests..