Thank you @giampiero for your suggestions. I have tried them all without success. Others who own the machine do not have the same experience with preinfusion; if the suggestion about Eco was the way to save a setting then it should be the case for 100% of users. It is not. Interestingly all other settings can be saved and are retained once the machine is switched back on which would indicate the microcontroller is not totally faulty. There may be just one logic gate that has failed??
What is also very interesting is that, now I have reset to factory defaults, Active is stuck at 4 seconds. So, clearly, the logic of writing to the NVM works fine otherwise the settings could not be reverted. So, I suspect, an error in coding somewhere.
The real issue for me, though, is that the design of the system does not allow a downloadable firmware to be flashed to fix an error. And of course no wifi or bluetooth so no remote upload of faults to ECM for diagnostic purposes.
My phone takes quite some time to auto focus, and I am using it one-handed, so apologies for the poor quality. Note the Active time (3 sec) compared to the same setting when I switch the machine back on (1 sec). Preinfusion