Adrianmsmith roger that. I’ll remove it and upload to YouTube when I do the next vid with the top panel off

Certainly looks a bit crusty. Will video shortly

    Tal there are some white residues that is a sign that something was leaking in the past. I have not witnessed the steam you have seen so back to Adrian’s advice, source a cheap antivac valve and replace it whilst you are at it or if you wish try to clean it/descale it and grease it properly. There might be still life in it.

    Current setup: ACS Vesuvius, Nuova Simonelli Mythos One. Past experience, Nuova Simonelli Apia 1 gr., San Remo Capri 1 gr., Bezzera BZ 35e, Fracino Heavenly. Anfim Super Lusso.

    Contact me at: john_yossarian11@yahoo.com

    Tal

    Youre not looking for leaking!!

    You are looking at the inside of the flexible tube.

    From the photo I would say that is the issue but this is a very clean machine for 5 years old. Just shows you the quality.

    Blue star are a good company If that is the exact part, I’ve had a few bits from them in the past

    Ade Smith. ACS Evo Leva v2. Kafatek Flat max 2, ssw 2024. Mazzer Philos, Craig Lyn HG-1 prime., WW key mk1.

    About Me

    • Tal replied to this.

      Tal

      With the fault you have, you are not in a desperate rush. I would email Maria and just ask what part they use and get a price. May be worth just paying them to send you one.

      Obviously anything will do so long as it has the same hose connector and thread or you have the thread adaptors.

      You may find it does clean and you do not need a new one, but just in case you damage it, I would get a new one first and then you have a spare 😎

      The one you have fitted has a compression fitting for the plastic tube so slightly different to the one you have sourced

      Ade Smith. ACS Evo Leva v2. Kafatek Flat max 2, ssw 2024. Mazzer Philos, Craig Lyn HG-1 prime., WW key mk1.

      About Me

      Tal

      This shows the fitting size

      Ade Smith. ACS Evo Leva v2. Kafatek Flat max 2, ssw 2024. Mazzer Philos, Craig Lyn HG-1 prime., WW key mk1.

      About Me

      • Tal likes this.

      Adrianmsmith

      So I am looking for water flow in that tube?

      Yeh i just grabbed a link for the first part I found. But fair yeh it doesn’t have the correct hose connection.

        Tal

        More like steam at that point, so condensation,

        Ade Smith. ACS Evo Leva v2. Kafatek Flat max 2, ssw 2024. Mazzer Philos, Craig Lyn HG-1 prime., WW key mk1.

        About Me

        Ok I’ve spotted something regarding that valve. Will upload shortly

        At 18s you will see the top of the valve wet out, shortly after it hits 1bar service boiler pressure and the steam in the drip tray stops

          Tal

          Unless @DavecUK has other advice

          I would order a new one and then decide if to clean or replace it.

          If you buy from ACS, Maria it will be a direct replacement and you won’t need and adaptors etc

          Its not like you need to do it tomorrow…..

          Include your photo from above for their info when you enquire.

          Ade Smith. ACS Evo Leva v2. Kafatek Flat max 2, ssw 2024. Mazzer Philos, Craig Lyn HG-1 prime., WW key mk1.

          About Me

          • Tal likes this.

          To me it looks like it needs 1bar or so to seal. But as it gets close to sealing the flow of steam must slow and condensation runs back towards the valve. Wetting the top of it as shown. Which is probably where all of the scale has come from around it.

          I will look in this thread for Maria’s email and get a part request fired off.

          Thank you everyone for helping

            Absolute star. Cheers

            Have fired off an email so hopefully get a response tomorrow.

            Hi again,

            Paolo has been helping me on a Sunday of all days, can’t ask for more than that.

            He suggested I remove the vacuum breaker and descale it. I did but couldn’t resist separating the plastic part from the metallic part. I didn’t take an photo for order of reassembly! Could anyone confirm the position of the smaller spring please?

            This

            Thanks

            Edit: have reassembled as above and believe that is correct

              Looking at the valve id prob descale it too

              It wont seal till it reaches pressure, so some steam and water is normal.

              Decent De1pro v1.45 - Niche Duo - Niche Zero - Decent is the best machine ever made -

                Cuprajake

                Haha, I did kick myself for a moment, fired back up and no change. But Paolo suggested that the boiler could be overfilling hence the steam. So I’ll pull the level sensor next and give that clean up.

                The fitting originally identified above though is definitely leaking, perhaps the hose just needs trimming off and refitting. Though that loop doesn’t look particularly long. I could get a fresh piece of hose instead. Will measure it shortly

                  Tal you have made nice progress. As @Adrianmsmith said, I second him 100%, drop Maria an email and get a spare. I did buy thermal probes, (one of the original ones, they were made of brass, gave up the ghost) and they were cheaper than anything available in the UK. One thing is they use DHL and this might come a bit on the dear side, but I would still buy from ACS.

                  Current setup: ACS Vesuvius, Nuova Simonelli Mythos One. Past experience, Nuova Simonelli Apia 1 gr., San Remo Capri 1 gr., Bezzera BZ 35e, Fracino Heavenly. Anfim Super Lusso.

                  Contact me at: john_yossarian11@yahoo.com