I purchased the Leva because I wanted a lever machine - had my eye on the first Vesuvius lever then on the Vostok finally this one !

I didn’t want a pump driven extraction and the ACS was the best out there – in addition I have liked what Corby has been involved with

As for the gear pump quicker ramp up probably but low ml/sec .

I do not know if you are aware but a smaller diameter basket ( 54 vs 58 ) will produce a lower total weight on the puck - in fact water pressure is a false indicator of what the puck is subject to. Dalla Corte with their 54mm makes this clear on their website - a 5 bar pre infusion on 54 is a lower total weight than it would be on a 58. This also was discussed with Paolo - as a consequence he managed to find springs for my machine that would give the 54 mm puck the same total weight as the 58mm would yield .

    selmerfudd but where you got the idea that I expect the safety system to work with no water i will never know

    well, lets try here…..

    selmerfudd 1- How come the safety system only works when the machine is turned on I thought it was a passive system not active?

    with the machine turned off it cant actually pump water it to the chamber unless im missing something basic here!

    As you are unique with your pre infusion requirements and the rest of the world is doing it wrong, then, as Dave suggested turn off the auto dump and set what ever pre-infusion you require. then end the shot at you unbelievably low setting. what volume are you looking for 60ml or something?

    your requirements are so far away from Normal its difficult to see what you are trying to achieve or prove.

    selmerfudd to my knowing the safety system has not been described as to how it functions, as you know it has been kept quite hush hush by ACS- as well as by Dave Corby

    its so simple there’s nothing hush hush about it. As an engineer im sure you can work out the flow and pressure differences produced by an open cylinder system as opposed to one single 1mm diameter hole. nothing more to it. lever rises (piston lowers) slowly due to pressure build up within the virtually closed cylinder. Basic engineering!

    I asked where you are as the links I gave were more relevant to the UK and Europe than the US or cloud cuckoo land.

    selmerfudd -whether it functions on a hydraulic or a purely mechanical system is anyones guess

    no guessing required its all well documented, but to check and analyse it requires the removal of 1 x No2 Ph head set screw and 4 x nuts with a 10mm AF spanner / wrench / socket. Simple enough for all of us, let alone an engineer.

    As for the Basket size even Lance agrees its a better size on this group than the 58mm, even if that’s a slight misquote!

    Anyway its good to see you are happy with your purchase. Its difficult to realise we have the same machine.

    Best coffee I’ve had from my many machines. more to the point its more precise and consistent. (Still waiting for J to sell the Decent though, if Graham doesn’t get there first) 😎

    Ade Smith. ACS Evo Leva v2. Kafatek Flat max 2, ssw 2024. Mazzer Philos, Craig Lyn HG-1 prime., WW key mk1.

    About Me

    selmerfudd Cuprajake

    I purchased the Leva because I wanted a lever machine - had my eye on the first Vesuvius lever then on the Vostok finally this one !

    I didn’t want a pump driven extraction and the ACS was the best out there – in addition I have liked what Corby has been involved with

    As for the gear pump quicker ramp up probably but low ml/sec .

    I do not know if you are aware but a smaller diameter basket ( 54 vs 58 ) will produce a lower total weight on the puck - in fact water pressure is a false indicator of what the puck is subject to. Dalla Corte with their 54mm makes this clear on their website - a 5 bar pre infusion on 54 is a lower total weight than it would be on a 58. This also was discussed with Paolo - as a consequence he managed to find springs for my machine that would give the 54 mm puck the same total weight as the 58mm would yield .

    you may be better off with a flair 58

    Ade Smith. ACS Evo Leva v2. Kafatek Flat max 2, ssw 2024. Mazzer Philos, Craig Lyn HG-1 prime., WW key mk1.

    About Me

      selmerfudd then do not post on an open forum, or block me if you do not like answers.

      You may be on the wrong forum if you are simply looking for everyone to agree with all of your opinions.

      Ade Smith. ACS Evo Leva v2. Kafatek Flat max 2, ssw 2024. Mazzer Philos, Craig Lyn HG-1 prime., WW key mk1.

      About Me

      Agreement no !! Courteous yes and more humility in discussion, you might be wrong leave space for that !!

      Maybe in future suggest - don’t tell people what to do !!

      selmerfudd well the gear pump could max out at 44mls if you wanted it to 🤷

      Enjoy your Evo, I suggest not over thinking every aspect of the machine and to just use it

      Decent De1pro v1.45 - Niche Duo - Niche Zero - Decent is the best machine ever made -

      DavecUK

      Dave you wrote

      "“No, machines will function correctly on water with a TDS of 3%, this is true of all machines. RODI which has 0% will probably function as well, but I have never used RODI water.”"

      Did you not review a countertop RO system called Osmio in a YouTube video - did you not mention you used that RO water in a Vesuvius E61 for 4 years - or did I miss understand ?

      Thx fir all your help

      Selmerfudd

        DavecUK

        Oh Sorry - how did you manage to use RO water at less than 3% TDS and have the water probes to function correctly - I was under the impression that “boiler water level probes” need mineral content to function correctly - ?

        Can I use distilled or demineralized water in my Leva Evo II ?? Or do I need to add minerals to it ?

        Again thanks

        No, it’s corrosive

        Use something like Dr pavlis

        Or just plain ro water it usually has 30-70 TDs

        Distilled or rodi will more likely not work

        Decent De1pro v1.45 - Niche Duo - Niche Zero - Decent is the best machine ever made -

        To add if you are concerned about scale etc use the lowest TDs water you can like pavlis then use drops post brew to alter the taste. Alot of the decent lot do that

        Decent De1pro v1.45 - Niche Duo - Niche Zero - Decent is the best machine ever made -

        As of now I use distilled water with additional third wave packets to make up for the lack of minerals -

        my DE1 can function without the added minerals , since there is no boiler involved however for taste i add the mineral content anyway !

        thx

        Adrianmsmith

        Yes the mod is indeed interesting-Thank you– I am new to the Coffeetime forum, so many of the discussions i have not yet perused .

        I also was concerned about the lower pressure attained with the safety system - as well as the overall weight discrepancy on the puck between 9 bar at 54mm and 9 bar at 58mm , well I managed to obtain 11.7 bar with safety ,close enough !

        I still want to experiment with the flush lever pre charge and pre infusion , but so far I have not spent much time studying how to best use the flush system - to see what benefits it could yield.

        thanks again interesting reading for sure

          selmerfudd

          First off im not suggesting anyone does the mod, it was more to show you how it works…..

          As for pre charge the best way is to set the flush lever so the pump engages as soon as you move the lever.

          Make sure you move the lever to the pump on point . Pause until the pump starts

          Get used to the speed required to move the lever so the pump stays on and you do not hit pre infusion pressure until the lever is at the bottom.

          Why……..

          By doing the above you will have very little air in the cylinder, only water.

          So what……

          This will give maximum pressure as air is easier to compress .

          Im not buying in to the need to go past 11 bars . Some people mod to lighter springs to achieve lower start pressures as they want 9 or 10 bars max.

          Psi is psi , or bar, at 20mm or 58mm.

          Kg dead weight will give lower psi at 58mm and 54mm

          Ade Smith. ACS Evo Leva v2. Kafatek Flat max 2, ssw 2024. Mazzer Philos, Craig Lyn HG-1 prime., WW key mk1.

          About Me

            selmerfudd

            I purchased this very early on. Its No2, originally purchased by Jake. (Dave has No1)

            Prior to that i had Evo1 and Vesuvius after realising the ECM Synchronika was not the holy grail!!

            Jakes, my coffee journey would be a good read when you have time ….

            https://coffeetime.freeflarum.com/d/572-my-coffee-journey/691

            Ade Smith. ACS Evo Leva v2. Kafatek Flat max 2, ssw 2024. Mazzer Philos, Craig Lyn HG-1 prime., WW key mk1.

            About Me

            @selmerfudd

            ……

            There you go .

            Alternatively You can easily achieve any start pressure you want by putting very slight pressure on the lever after it settles.

            @DavecUK Just for you, you will see the standard ACS flush lever arm is fitted 😎

            Ade Smith. ACS Evo Leva v2. Kafatek Flat max 2, ssw 2024. Mazzer Philos, Craig Lyn HG-1 prime., WW key mk1.

            About Me